60
HP ProLiant DL380 Generation 4 Server Reference and Troubleshooting Guide
5. Install the DIMM.
7. If you are installing DIMMs in an online spare configuration, use RBSU to
Hot-Plug SCSI Hard Drive Options
When adding SCSI hard drives to the server, observe the following general
guidelines:
·
·
·
·
·
A maximum of 14 SCSI devices per channel can be added.
Each SCSI drive must have a unique ID. The system automatically sets all
SCSI IDs.
The SCSI ID for each hot-plug hard drive is set automatically to the next
sequential ID number in a series beginning with ID0.
If only one SCSI hard drive is used, install it in the bay with the lowest
number.
Hot-plug hard drives must be either Wide Ultra2, Ultra3, or Ultra320 SCSI
types. Mixing these types with other drive standards degrades the overall
performance of the drive subsystem.